SPEC IRONFORCE WITH CONFIDENCE.
Fully welded steel panel systems in three series, stocked and shipped from Las Vegas. Below is every document we can put in your hands — and an honest account of what we’re still building.
System Selection at a Glance
Member sizes and gauges below are read directly from the product catalog that drives our spec sheets and pricing. Panels are welded steel with a nominal 94 in panel length (approximately 7.83 ft of nominal coverage).
Values shown are published catalog data as of the date this page was generated and are subject to change without notice. Nominal dimensions are for preliminary layout only. Confirm current sizes, availability, and tolerances in writing before fabrication or before issuing a project manual.
| Series | Application | Heights | Top Styles | Picket | Rail | Panels |
|---|---|---|---|---|---|---|
| R100 R100 Residential | Residential | 4', 5', 6' | Flat Top, Pinched Security Top | 5/8 x 5/8 in, 18 ga | 1 x 1 in, 16 ga | 4 |
| C200 C200 Commercial | Commercial | 6' | Flat Top, Pinched Security Top | 3/4 x 3/4 in, 16 ga | 1-1/2 x 1-1/2 in, 14 ga | 2 |
| P300 P300 Perimeter | Perimeter | 7', 8' | Flat Top, Pinched Security Top, Arched Pinched Security Top | 3/4 x 3/4 in, 16 ga | 1-1/2 x 1-1/2 in, 14 ga | 6 |
Documentation Library
We label each item plainly. Available now means you can open it on this site today. On request means we produce it for your specific project. In development means it is not published yet — we would rather tell you than have it fail in plan check.
Specification Documents
CSI three-part format sections written for direct inclusion in your project manual.
Draft three-part specification covering the R100, C200, and P300 systems. Bracketed items indicate project-specific selections and data still being verified.
OpenThe same section delivered as a .doc file your spec writer can edit directly in the project manual.
Short-form paragraph naming IronForce as basis of design, with the substitution criteria a competing product would have to meet.
Product Data
Dimensional and material data for every panel in the catalog, in the format submittals require.
One-page branded PDF per panel: dimensioned drawing, picket and rail specification, spacing, coverage, and matched post and mounting components.
OpenEvery series, height, and top style with matched posts, brackets, and caps in a single reference document.
Standard finish, available custom colors, minimum order quantities, and the lead-time impact of a non-standard color.
Drawings and BIM
Detail geometry you can drop straight into a drawing set or a model.
Scaled elevation for each panel showing overall size, picket count, spacing, and rail positions. Currently published inside each spec sheet and on every product page.
OpenTypical panel elevation, post footing and embedment, panel-to-post connection, corner and end conditions, slope transitions, and mounting to concrete or masonry.
Parametric family with height, top style, picket spacing, and finish exposed as type parameters.
Layout, panel schedule, and connection details prepared against your drawing set once a project is awarded.
Structural and Performance Data
The engineering backup a plan reviewer will ask for. Being formalized — talk to us early on projects that need it.
Allowable design wind pressure by panel height and post spacing, with corresponding footing and embedment requirements.
Project-specific calculations sealed for your jurisdiction, prepared for submittal and plan check.
Forced-entry delay and impact performance data for the P300 perimeter series.
Compliance, Finish and Warranty
Product documentation for the project manual and the closeout package. Applicability to any specific code, standard, or credit is determined by the Architect of Record and the authority having jurisdiction.
Third-party laboratory results, where available, for salt spray, adhesion, impact, and humidity resistance, together with the substrate galvanizing designation and measured coating thickness. Laboratory results describe tested samples under test conditions and are not a prediction of field service life.
Stated term, covered conditions, exclusions, and transferability — the document your Part 1 warranty paragraph can cite.
Dimensional and configuration data to support the design team’s own review of barrier, guard, and gate hardware provisions. We do not issue code compliance determinations.
Available recycled content and point of manufacture information. Credit eligibility is determined by the rating system and the project team, not by IronForce.
Submittal Support
Everything the contractor has to hand you for approval, assembled in advance.
Product data, dimensioned drawings, finish information, and any available third-party documentation compiled per SKU for a single approval review.
Picket and rail section samples with the production finish, shipped to your office for material board review.
A working session with your team covering system selection, detailing, and where welded panel construction changes the detail from a typical picket fence.